Chapter 3. SVA Path Operation 23
Understanding the setsp -a Screen
Use the setsp -a command to display the default path
configurations.
Figure 3-1 Sample Output of setsp -a Command
The column headings identify the various fields on this screen, the
last seven of which are user-configurable parameters for the
device. The
setsp -a output fields (with their default values,
when applicable) are described below. The commands used to
change the default settings are described in the following section.
spd is the SVA Path driver number, an ID assigned to the
device by SVA Path and the name of the spd special device
file created by SVA Path to access the storage. The spd
device is displayed in the form spdN = cXtYdZ, and
provides the spd number (
N in the spdN field) and the virtual
device name (in the format cXtYdZ). This device number
also appears in errors reported in the
/var/adm/syslog/syslog.log file.
Path/disk shows the device names and disk numbers for
each of the redundant physical paths to the device. Their
appearance in the
setsp -a output facilitates interpreting
these events in terms of the spd device names by which
applications access devices. This field shows the disk
number in the form of cXtYdZ.
# setsp -a
===============================================================================
spd Path/disk Status Primary Exclude Buf Balance RtrCnt RtrDly FailBack
===============================================================================
0 c0t1d0 Good X X 32 1 20 3000 1
c3t0d0 Good X
spd0 = c83t0d0 ID = "STK 9500 0000000010390000"
===============================================================================
1 c0t1d1 Good X 32 1 20 3000 1
c3t0d1 Good X X
spd1 = c83t0d1 ID = "STK 9500 0000000010390001"
===============================================================================
2 c0t1d2 Good X X 32 1 20 3000 1
c3t0d2 Good X
spd2 = c83t0d2 ID = "STK 9500 0000000010390002"
===============================================================================
Vedere la pagina 32