Chapter 5. Diagnosing Errors 53
Errors for other spd devices, representing the same physical I/O
path that was interrupted by the pulled cable, will be reported, as
shown in Figure 5-4, “Additional Messages for the Same Pulled
Cable”.
Figure 5-4 Additional Messages for the Same Pulled Cable
Even when an spd device is idle, a SCSI Test Unit Ready
command is sent periodically to the device to confirm that it is
functioning. A failure of this test is reported in the syslog.log file
as illustrated in Figure 5-4, “Additional Messages for the Same
Pulled Cable”.
Failover Error Reporting
/var/adm/syslog/syslog.log records failover events as
well..
Figure 5-5 The Failover Event
The event in Figure 5-5, “The Failover Event” records that I/O for
the device spd0 will be redirected from path 0 (c6t0d0) to path
1 (c7t0d0), the alternate path. The output from setsp -a (Figure
5-6, “setsp -a Output after the Failed Path Is Detected”) now
Jun 30 14:58:28 n4000 vmunix: ALERT: fcT1 (1, 735458, 0/5/0/0) Fibre
Channel Driver received an interrupt indicating a Link Failure. The Frame
Manager Status Register is 0x980010D0.
Jun 30 14:58:31 n4000 vmunix: spd2: path 0 error
Jun 30 14:58:36 n4000 vmunix: ALERT: fcT1 (1, 712251, 0/5/0/0) Fibre
Channel Driver received an interrupt indicating a Link Failure. The Frame
Manager Status Register is 0x980010D0.
Jun 30 14:58:40 n4000 vmunix: spd1: path 0 error
Jun 29 13:53:44 n4000 vmunix: spd0: path failover from 0 to 1.