Command Line Interface Reference InForm OS Version 2.2.4
The following examples display both standard and detailed information about SFPs attached
to ports:
NOTES
See Restrictions on page 10.17 for important information regarding port modes and port pair
protection.
cli% showport -sfp
N:S:P -State- -Manufacturer- MaxSpeed(Gbps) TXDisable TXFault RXLoss DDM
0:0:1 OK FINISAR_CORP. 2.10 No No No Yes
0:0:2 OK FINISAR_CORP. 2.10 No No Yes Yes
0:3:2 OK SIGMA-LINKS 2.10 No No Yes Yes
1:0:1 OK FINISAR_CORP. 2.10 No No No Yes
1:0:2 OK FINISAR_CORP. 2.10 No No Yes Yes
cli%
root@enodea5:~# showport -sfp -d
------------Port 0:0:2------------
N:S:P : 0:0:2
State : Degraded
Manufacturer : PICOLIGHT
Part Number : PL-XPL-VE-S24-31
Serial Number : 425EF1E6
Revision : N/A
MaxSpeed(Gbps): 2.10
Qualified : No
TX Disable : --
TX Fault : --
RX Loss : --
RX Power Low : No
DDM Support : No
----------Port 1:3:1-----------
N:S:P : 1:3:1
State : OK
Manufacturer : FINISAR_CORP.
Part Number : FTLF8519P2BNL
Serial Number : U76031S
Revision : A
MaxSpeed(Gbps): 2.10
Qualified : Yes
TX Disable : No
TX Fault : No
RX Loss : No
RX Power Low : No
DDM Support : Yes