Release Notes 23
MPIO
MPIO DSM 2.0.0.13 does not support Microsoft Cluster. The current release of the
R/Evolution MPIO DSM does not correctly implement a feature required for
Microsoft Cluster.
Documentation Issues
The Getting Started Guide describes point-to-point cabling. Point-to-point cabling is
not supported. Use loop mode only.
The Getting Started Guide should specify that the supported browsers can be later
versions of Firefox or Opera.
ThecommandsintheCLIaredescribedinboththeCLI Reference Manual and in
the on-line help system. Table 13 summarizes changes between the commands and
their descriptions in the manual and on-line help.
Table 13 CLI Documentation Issues
Command
On-line Help
CLI Reference Manual
create vdisk
The spares parameter should be spare (singular). On-line help
only.
expand
vdisk
There should be a caution that this command can take hours or days
to complete. CLI Reference Manual only.
restart The caution should state: “If you shut down the controller you are
connected to, your connection is lost until the restart is complete. If
you shut down both controllers, you and users lose access to the array
and its data until the restart is complete.” On-line help only.
show cache-parameters The Volume Serial and Volume Name fields are omitted.
show cli-parameters The Timeout field is in the wrong position, and Session Output
Format should be Output Format.
show configuration Instead of ENCLOSURE STATUS as documented, the output has
sections titled SES and ENCLOSURE COMPONENTS, and there are
separate sections for MIDPLANE FRU and ENCLOSURE FRU
information.
show controller-date The correct field name is Controller Date.
show disks The Rate (Gb/s) field is omitted.