Document number: 55-16-001-002April, 20151 / 122CHARON-SSP for Linux - User'sGuide

Pagina 2 - Contents

Document number: 55-16-001-002© Stromasys, 201510 / 122i686 glibc Installation OutputLoaded plugins: langpacksResolving Dependencies--> Running tra

Pagina 3 - About This Guide

Document number: 55-16-001-002© Stromasys, 2015100 / 122Syntax "machine = model-name"DescriptionThe model keyword is used to indicate the sp

Pagina 4 - Conventions

Document number: 55-16-001-002© Stromasys, 2015101 / 122[ttya] SectionThe ttya section is used to configure the first serial port (sometimes used as t

Pagina 5 - Introduction

Document number: 55-16-001-002© Stromasys, 2015102 / 122DescriptionThis option configures how the serial console port will be connected. The table be

Pagina 6 - Host System Requirements

Document number: 55-16-001-002© Stromasys, 2015103 / 122[ttyb] SectionThe ttya section is used to configure the first serial port (sometimes used as t

Pagina 7 - Supported Virtual Hardware

Document number: 55-16-001-002© Stromasys, 2015104 / 122

Pagina 8 - Installation

Document number: 55-16-001-002© Stromasys, 2015105 / 122Console ReferenceThe CHARON-SSP SPARC virtual machines use a subset of the Sun OpenBoot consol

Pagina 9

Document number: 55-16-001-002© Stromasys, 2015106 / 122bannerDisplay power-on banner.SyntaxbannerDescriptionUse this command to display the power-on

Pagina 10

Document number: 55-16-001-002© Stromasys, 2015107 / 122bootLoad operating system.Syntaxboot [ ] [ ]device-alias boot-argsDescriptionThis commands

Pagina 11 - Post-Installation Tasks

Document number: 55-16-001-002© Stromasys, 2015108 / 122devaliasDisplay device aliases.SyntaxdevaliasDescriptionThis commands display the current devi

Pagina 12

Document number: 55-16-001-002© Stromasys, 2015109 / 122helpDisplay OpenBoot console help.Syntaxhelp [ ]commandDescriptionUse this command to displa

Pagina 13

Document number: 55-16-001-002© Stromasys, 201511 / 122Sentinel HASP Installation OutputLoaded plugins: langpacksExamining aksusbd-2.2.1-1.x86_64.rpm:

Pagina 14

Document number: 55-16-001-002© Stromasys, 2015110 / 122historyDisplay console command history.SyntaxhistoryDescriptionThis command displays a list of

Pagina 15

Document number: 55-16-001-002© Stromasys, 2015111 / 122printenvDisplay environment variables.SyntaxprintenvDescriptionUse this command to print the c

Pagina 16

Document number: 55-16-001-002© Stromasys, 2015112 / 122probe-scsiScan SCSI bus for attached devices.Syntaxprobe-scsiDescriptionThis command scan the

Pagina 17

Document number: 55-16-001-002© Stromasys, 2015113 / 122quitShutdown virtual machine.SyntaxquitDescriptionUse this command to shutdown the virtual mac

Pagina 18

Document number: 55-16-001-002© Stromasys, 2015114 / 122resetRestart the system.SyntaxresetDescriptionThis command restarts the SPARC virtual machine.

Pagina 19

Document number: 55-16-001-002© Stromasys, 2015115 / 122setenvSet console environment variables.Syntaxsetenv variable valuesetenv --variableDescript

Pagina 20 - Post Installation Tasks

Document number: 55-16-001-002© Stromasys, 2015116 / 122show-devsDisplay device tree.Syntaxshow-devsDescriptionThis command displays the tree of devic

Pagina 21

Document number: 55-16-001-002© Stromasys, 2015117 / 122Command Line Utilities ReferenceIn many cases it may be preferrable to be able to perform main

Pagina 22

Document number: 55-16-001-002© Stromasys, 2015118 / 122hasp_srm_viewNamehasp_srm_view –CHARON Sentinel HASP UtilitySynopsishasp_srm_view [OPTION]Desc

Pagina 23

Document number: 55-16-001-002© Stromasys, 2015119 / 122License Manager running at host: localhost.localdomainLicense Manager IP address: 127.0.0.1 T

Pagina 24

Document number: 55-16-001-002© Stromasys, 201512 / 122Instructions for Securing Sentinel HASP GUIStep Description1.Open a web browser and navigate th

Pagina 25

Document number: 55-16-001-002© Stromasys, 2015120 / 122hasp_updateNamehasp_update –Sentinel HASP Update and Transfer UtilitySynopsishasp_update u fil

Pagina 26 - Post Removal Tasks

Document number: 55-16-001-002© Stromasys, 2015121 / 122mkdskcmdNamemkdskcmd –CHARON virtual disk container creation utility.Synopsismkdskcmd [OPTION]

Pagina 27

Document number: 55-16-001-002© Stromasys, 2015122 / 122This example creates a virtual disk container file, , using a block size of 4,096 bytes and a

Pagina 28

Document number: 55-16-001-002© Stromasys, 201513 / 122Sentinel HASP Uninstall OutputLoaded plugins: langpacksResolving Dependencies--> Running tra

Pagina 29 - Securing the Configuration

Document number: 55-16-001-002© Stromasys, 201514 / 122Installing the CHARON-SSP SoftwareThe CHARON-SSP for Linux virtual machine software is shipped

Pagina 30

Document number: 55-16-001-002© Stromasys, 201515 / 122CHARON-SSP/4M for GNU/Linux Install Output# yum localinstall charon-ssp-4m-1.0.22-x86_64.rpmExa

Pagina 31

Document number: 55-16-001-002© Stromasys, 201516 / 122Removing the CHARON-SSP SoftwareTo install the CHARON-SSP for Linux virtual machine software, e

Pagina 32

Document number: 55-16-001-002© Stromasys, 201517 / 122Upgrading CHARON-SSP for LinuxTo upgrade the CHARON-SSP for Linux software, simply follow the i

Pagina 33 - Installation Tasks

Document number: 55-16-001-002© Stromasys, 201518 / 122Installing the CHARON-SSP ManagerThe CHARON-SSP Manager client software is available for both W

Pagina 34

Document number: 55-16-001-002© Stromasys, 201519 / 122Installing CHARON-SSP Manager for WindowsThe following sections cover the procedures for instal

Pagina 35

2 / 122Contents About This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 36

Document number: 55-16-001-002© Stromasys, 201520 / 122Installing CHARON-SSP Manager for WindowsStep Description1.Right-click the zip archive, and s

Pagina 37 - License Security

Document number: 55-16-001-002© Stromasys, 201521 / 122It is also recommended by Stromasys that is checked for any critical Microsoft .NET Framework

Pagina 38

Document number: 55-16-001-002© Stromasys, 201522 / 122Microsoft Windows XP and Server 2003Removing CHARON-SSP Manager from Microsoft Windows XP and S

Pagina 39 - Using the CHARON-SSP Software

Document number: 55-16-001-002© Stromasys, 201523 / 122Installing the CHARON-SSP Manager for LinuxThe following sections cover the procedures for inst

Pagina 40 - Using the CHARON-SSP Manager

Document number: 55-16-001-002© Stromasys, 201524 / 122CHARON-SSP Manager for Linux Install OutputLoaded plugins: langpacksExamining charon-manager-ss

Pagina 41 - 41 / 122

Document number: 55-16-001-002© Stromasys, 201525 / 1222. Add the following text to the file created in step 1 and save it.[Desktop Entry]Version=1.0.

Pagina 42 - Managing Virtual Machines

Document number: 55-16-001-002© Stromasys, 201526 / 122CHARON-SSP Manager for Linux Uninstall OutputLoaded plugins: langpacksResolving Dependencies--&

Pagina 43 - Modifying a Virtual Machine

Document number: 55-16-001-002© Stromasys, 201527 / 122Upgrading CHARON-SSP Manager for LinuxTo upgrade the CHARON-SSP Manager for Linux software, sim

Pagina 44 - Model Configuration

Document number: 55-16-001-002© Stromasys, 201528 / 122Installing the CHARON-SSP AgentThe CHARON-SSP Agent for Linux software is shipped as a tar, gzi

Pagina 45 - CPU Configuration

Document number: 55-16-001-002© Stromasys, 201529 / 122CHARON-SSP Agent for Linux Install OutputLoaded plugins: langpacksExamining charon-agent-ssp-1.

Pagina 46 - 46 / 122

Document number: 55-16-001-002© Stromasys, 20153 / 122About This GuideThis preface describes the conventions and organisation of this user's guid

Pagina 47 - Memory Configuration

Document number: 55-16-001-002© Stromasys, 201530 / 122Removing the CHARON-SSP Agent SoftwareTo remove the CHARON-SSP Agent for Linux software, execut

Pagina 48 - SCSI Configuration

Document number: 55-16-001-002© Stromasys, 201531 / 122Upgrading CHARON-SSP/4M for Linux# yum localinstall charon-agent-ssp-1.0.22-x86_64.rpm Loaded p

Pagina 49 - Creating Container Files

Document number: 55-16-001-002© Stromasys, 201532 / 122Installing the CHARON-SSP Virtual EnvironmentThe CHARON-SSP Virtual Environment is an appliance

Pagina 50

Document number: 55-16-001-002© Stromasys, 201533 / 122Installation TasksCHARON-SSP Installation TasksStep Description1. If the host system is a virtu

Pagina 51 - Add/Edit Virtual SCSI Device

Document number: 55-16-001-002© Stromasys, 201534 / 1223. When presented with the following screen:Select and press Return.Finish partitioning and w

Pagina 52 - 52 / 122

Document number: 55-16-001-002© Stromasys, 201535 / 1224. The base installation will now continue. At completion the system will reboot.Ensure that th

Pagina 53 - TTYA Configuration

Document number: 55-16-001-002© Stromasys, 201536 / 122CHARON-SSP Manager Password Change InstructionsStep Description1.Log in to the CHARON-SSP Manag

Pagina 54 - Physical Console Device

Document number: 55-16-001-002© Stromasys, 201537 / 122Change CHARON-SSP Virtual Environment PasswordThe CHARON-SSP Virtual Environment runs under the

Pagina 55 - Network Console Device

Document number: 55-16-001-002© Stromasys, 201538 / 122CHARON-SSP Virtual Evnrionment Upgrade InstructionsStep Description1.Double-click the icon labe

Pagina 56 - TTYB Configuration

Document number: 55-16-001-002© Stromasys, 201539 / 122Using the CHARON-SSP SoftwareThe following sections describe in detail each of the individual p

Pagina 57 - Ethernet Configuration

Document number: 55-16-001-002© Stromasys, 20154 / 122Europe, Middle-East and [email protected]+41 22 794 1070 Avenue Louis-Casai 845th F

Pagina 58 - Log Configuration

Document number: 55-16-001-002© Stromasys, 201540 / 122Using the CHARON-SSP ManagerThe CHARON-SSP Manager is a GUI management interface for the CHARON

Pagina 59 - Renaming a Virtual Machine

Document number: 55-16-001-002© Stromasys, 201541 / 122

Pagina 60

Document number: 55-16-001-002© Stromasys, 201542 / 122Managing Virtual MachinesThe following sections describe the different aspects of managing a CH

Pagina 61 - Removing a Virtual Machine

Document number: 55-16-001-002© Stromasys, 201543 / 122CHARON-SSP Manager Opening ScreenModifying a Virtual Machine Whether completing configuration o

Pagina 62 - Managing Virtual Networks

Document number: 55-16-001-002© Stromasys, 201544 / 122Edit Virtual Machine Settings WindowThe following section describes each part of the window V

Pagina 63 - Resizing a Virtual Network

Document number: 55-16-001-002© Stromasys, 201545 / 122Virtual Machine Model Configuration Window The models currently supported by CHARON-SSP/4M for

Pagina 64 - Managing Licenses

Document number: 55-16-001-002© Stromasys, 201546 / 122Virtual Machine CPU Configuration Window The following table lists each of the fields in the CP

Pagina 65 - Gathering Host Information

Document number: 55-16-001-002© Stromasys, 201547 / 122Virtual Machine CPU Configuration FieldsField DescriptionNumber ofCPUConfigure the number of CP

Pagina 66 - Preferences Window

Document number: 55-16-001-002© Stromasys, 201548 / 122Virtual Machine Memory Configuration Widows The following table lists each of the fields in the

Pagina 67

Document number: 55-16-001-002© Stromasys, 201549 / 122Virtual Machine SCSI Configuration Window From this window it is possible to create virtual dis

Pagina 68 - Interactive Mode

Document number: 55-16-001-002© Stromasys, 20155 / 122IntroductionIn 1987 Sun Microsystems released the SPARC V7 processor. A 32-bit RISC processor f

Pagina 69

Document number: 55-16-001-002© Stromasys, 201550 / 122Create New Virtual Disk Window To create a virtual disk container file, follow the instruction

Pagina 70

Document number: 55-16-001-002© Stromasys, 201551 / 122Create New Virtual Tape WindowsTo create a virtual tape container file, follow the instructions

Pagina 71 - Open Boot Console Ouptut

Document number: 55-16-001-002© Stromasys, 201552 / 122Add/Edit Virtual Disk Device Window (CHARON-SSP/4M shown)The following table lists each of the

Pagina 72 - Using the CHARON-SSP Agent

Document number: 55-16-001-002© Stromasys, 201553 / 122Add/Edit Virtual Disk Device Configuration FieldsField DescriptionSCSIdevicetype Drop-down list

Pagina 73 - Accessing the Console

Document number: 55-16-001-002© Stromasys, 201554 / 122Virtual Machine TTYA Configuration WindowIt is possible to configure the virtual console device

Pagina 74

Document number: 55-16-001-002© Stromasys, 201555 / 122Virtual Machine TTYA Physical Device Configuration WindowThe only option for the physical termi

Pagina 75 - Graphical Console Access

Document number: 55-16-001-002© Stromasys, 201556 / 122Virtual Machine TTYA Network Device Configuration WindowThe following table lists each of the f

Pagina 76 - Starting the Xserver

Document number: 55-16-001-002© Stromasys, 201557 / 122to TTYA. For further details related to configuring this device, consult the section .TTYA Co

Pagina 77 - Stopping the Xserver

Document number: 55-16-001-002© Stromasys, 201558 / 122Virtual Ethernet Configuration FieldsField DescriptionInterface Select the host attached Ethern

Pagina 78 - License Management

Document number: 55-16-001-002© Stromasys, 201559 / 122Virtual Machine Logging Configuration FieldsField DescriptionLogpathSpecify the path name for t

Pagina 79 - Viewing the License Details

Document number: 55-16-001-002© Stromasys, 20156 / 1221. 2. 3. Host System RequirementsTo ensure maximum performance when emulating an SPARC-based

Pagina 80

Document number: 55-16-001-002© Stromasys, 201560 / 122Renaming a Virtual MachineStep Description1.Click the virtual machine to rename in the left han

Pagina 81

Document number: 55-16-001-002© Stromasys, 201561 / 122Removing a Virtual Machine The complete removal of a virtual machine must be performed in a num

Pagina 82

Document number: 55-16-001-002© Stromasys, 201562 / 122Managing Virtual NetworksUsing the CHARON-SSP Agent in conjunction with the CHARON-SSP Manager

Pagina 83

Document number: 55-16-001-002© Stromasys, 201563 / 122Instructions for Deleting a Virtual NetworkStep Description1.Follow the menu path Tools > Vi

Pagina 84 - Displaying Attached Licenses

Document number: 55-16-001-002© Stromasys, 201564 / 122Managing LicensesThe process of managing CHARON-SSP for Linux is described in full detail in th

Pagina 85

Document number: 55-16-001-002© Stromasys, 201565 / 122Miscellaneous Management TasksThe following sections describe some other miscellaneous function

Pagina 86

Document number: 55-16-001-002© Stromasys, 201566 / 122About CHARON Manager Windows The example above shows the window for CHARON-SSP Manager versio

Pagina 87 - Configuration Reference

Document number: 55-16-001-002© Stromasys, 201567 / 122Using CHARON-SSP from the Command LineNamess20 – CHARON-SSP/4M 32-bit SPARC V8, sun4m Architect

Pagina 88

Document number: 55-16-001-002© Stromasys, 201568 / 122 Command Line Utility OptionssmaOption Description -a alias_nameAssign to the new virtual mac

Pagina 89 - [cpu] Section

Document number: 55-16-001-002© Stromasys, 201569 / 122The following command reference describes the syntax and operation of the commands supported in

Pagina 90 - [ethernet] Section

Document number: 55-16-001-002© Stromasys, 20157 / 122Supported Virtual HardwareThe different classes of CHARON-SSP virtual machine support a number o

Pagina 91 - [ethernet_n] Section

Document number: 55-16-001-002© Stromasys, 201570 / 122Example SPARCstation 20 Configuration[system]model = "SPARCstation_20" [ram]size = 64

Pagina 92 - [log] Section

Document number: 55-16-001-002© Stromasys, 201571 / 122Open Boot Console Ouptut SMCC SPARCstation 20 Emulator by Stromasys CPU_#0 TI,

Pagina 93 - Logging Severity Levels

Document number: 55-16-001-002© Stromasys, 201572 / 122Using the CHARON-SSP AgentThe CHARON-SSP Agent is a Linux service that runs on a system that wi

Pagina 94 - [nvram] Section

Document number: 55-16-001-002© Stromasys, 201573 / 122Accessing the ConsoleDepending on how the virtual machine console device has been configured, i

Pagina 95 - [ram] Section

Document number: 55-16-001-002© Stromasys, 201574 / 122CHARON-SSP Manager Console Tab To configure the serial console to be accessed from the CHARON-S

Pagina 96 - [scsi_n] Section

Document number: 55-16-001-002© Stromasys, 201575 / 122Console Access from the NetworkThe serial console can also be configured for remote access acro

Pagina 97 - Virtual Storage Device Types

Document number: 55-16-001-002© Stromasys, 201576 / 122Enabling XDMCPBefore switching to the Xserver, it is first necessary to ensure that XDMCP is en

Pagina 98 - [scsix_n] Section

Document number: 55-16-001-002© Stromasys, 201577 / 122Instructions for Starting the X11 ServerStep Description1.Open the window (shown below) from

Pagina 99 - [system] Section

Document number: 55-16-001-002© Stromasys, 201578 / 1221. 2. 3. 4. License ManagementAll Stromasys CHARON virtual machine software products are li

Pagina 100 - Virtual Machine Model Names

Document number: 55-16-001-002© Stromasys, 201579 / 122Managing Licenses with CHARON-SSP ManagerThe CHARON-SSP Manager provides a friendly graphical i

Pagina 101 - [ttya] Section

Document number: 55-16-001-002© Stromasys, 20158 / 122InstallationThe CHARON-SSP for Linux suite of products provides much more than just a SPARC virt

Pagina 102 - Virtual Serial Port Types

Document number: 55-16-001-002© Stromasys, 201580 / 122Gathering Customer to Vendor (C2V) Detail The following steps describe the process of gathering

Pagina 103 - [ttyb] Section

Document number: 55-16-001-002© Stromasys, 201581 / 1221. 2. Applying Vendor to Customer (V2C) License UpdateAfter sending the C2V (customer to vend

Pagina 104 - 104 / 122

Document number: 55-16-001-002© Stromasys, 201582 / 122Managing Licensing from the Command LineThe CHARON-SSP Agent provides two command line utilitie

Pagina 105 - Console Reference

Document number: 55-16-001-002© Stromasys, 201583 / 1221. 2. Command to Gather Customer to Vendor Data File$ hasp_srm_view -c2v /path/to/keydata.c2v

Pagina 106 - Description

Document number: 55-16-001-002© Stromasys, 201584 / 122Using the SafeNet Sentinel Admin Control CenterThe SafeNet Sentinel Admin Control Center (ACC)

Pagina 107 - Example Command Outputboot

Document number: 55-16-001-002© Stromasys, 201585 / 122SafeNet Sentinel Admin Control Center - Sentinel Keys Applying V2C (Vendor to Customer) License

Pagina 108

Document number: 55-16-001-002© Stromasys, 201586 / 1221. 2. Applying a License Key File with SafeNet Sentinel ACCStep Description1. Save the V2C (

Pagina 109 - Example Command Outputhelp

Document number: 55-16-001-002© Stromasys, 201587 / 122Configuration ReferenceThe CHARON-SSP virtual machines can be configured using a text-based con

Pagina 110

Document number: 55-16-001-002© Stromasys, 201588 / 122ReferenceThe following sections describe how to manipulate the configuration objects and their

Pagina 111

Document number: 55-16-001-002© Stromasys, 201589 / 122[cpu] SectionThis section controls options related to the operation of the virtual machines CPU

Pagina 112

Document number: 55-16-001-002© Stromasys, 20159 / 122Installing the Sentinel HASP SoftwareThe Sentinel HASP runtime is a necessary software component

Pagina 113

Document number: 55-16-001-002© Stromasys, 201590 / 122[ethernet] SectionThis section describes the virtual Ethernet adapters attached to the virtual

Pagina 114 - Example Command Outputreset

Document number: 55-16-001-002© Stromasys, 201591 / 122[ethernet_n] SectionThis section is used for virtual machine configurations where there are mul

Pagina 115 - Variablessetenv

Document number: 55-16-001-002© Stromasys, 201592 / 122[log] SectionThis section describes the configuration of the CHARON-SSP for Linux virtual machi

Pagina 116

Document number: 55-16-001-002© Stromasys, 201593 / 122severity Logging severity level.Syntax = severity levelDescriptionVirtual machine logging messa

Pagina 117 - Reference

Document number: 55-16-001-002© Stromasys, 201594 / 122[nvram] SectionThis section is used to configure the location of the NVRAM backing file store a

Pagina 118 - Examples

Document number: 55-16-001-002© Stromasys, 201595 / 122[ram] SectionThis section controls the virtual machine memory environment. The following list

Pagina 119

Document number: 55-16-001-002© Stromasys, 201596 / 122[scsi_n] SectionThis section describes the virtual SCSI storage device configuration. Each dev

Pagina 120

Document number: 55-16-001-002© Stromasys, 201597 / 122Virtual Storage Device TypesDevice Type Description Example Pathcdrom Physical optical device.

Pagina 121

Document number: 55-16-001-002© Stromasys, 201598 / 122[scsix_n] SectionThese sections are used for virtual machine configurations that support the ex

Pagina 122

Document number: 55-16-001-002© Stromasys, 201599 / 122[system] SectionThe system section is used to configure "system-wide" properties of t